Detail Specifications / Descriptions
1) Max. continuous output power : 200W
2) Max. continuous output power 2H. : 225W
3) Surge capability peak output power : 400W
4) DC input static current (no load ): ≤0.4AMP
5) AC output wave form : Modified Sine wave
6) Normal input voltage range : 11-15V / 21~30V
7) High voltage cut off level : >15V / 30V
8) Low voltage alarm : 10.6V±0.3V(DC12V) / 20.5V±0.5V(DC24V)
9) Low voltage cut off level : 9.5V±0.5V(DC12V) / 19.5V±0.5V(DC24V)
10) Output AC voltage : AC 115V±5% RMS / AC 230V ±5% RMS
11) Output frequency level : 60HZ±1Hz / 50HZ
12) Overload power range : 200W, 5-30%
13) Hi-pot test : PRI / sec, 1500V / AC 5mA/60s
14) Temperature protection : <65°C
15) Full load max. optimum efficiency : ≥90%
16) AC output short circuit protection : system shut down (no damage)
17) Fan run : Working with load
18) Fault warning : alarm beep
19) LED indicator :
a) Normal : green
b) Fault : red green
20) Fuse (spade type) : 25Ax 1pcs
21) Dimensions (L x W x H) : 110x 88 x 47mm
22) Environmental condition :
a) Operating temperature : -5~45°C
b) Operating relative humidity : 10-90% RH
c) Storage temperature : -10~50°C
d) Storage relative humidity : 10-95% RH